20
Cue Site Manager / Programmer’s Manual / CSMDataProvider (driver)
Property Name Data Type Allowed Values Default Value Description
CUEunits
CueUnit01Name Text Max length = 50 Empty Name of monitored
CUEunit 1
... ... ... ... ...
CueUnit10Name Text Max length = 50 Empty Name of monitored
CUEunit 10
Parameter01 – Parameter10
ParameterXXName Text Max length = 50 Empty Name of monitored
parameter
ParameterXXUnit Text Max length = 20 Empty Unit of parameter
ParameterXXThresholdValue Double Any 0 Threshold value of
parameter
ParameterXXThresholdOperator Long LessThen := 1
LessThenOrEqualTo := 2
GreaterThen := 3
GreaterThenOrEqualTo := 4
EqualTo := 5
NotEqualTo := 6
GreaterThen := 3 Threshold operator.
Symbolically: If
[ParameterValue]
Operator
[TresholdValue] =
True, then Action is
performed
ParameterXXThresholdAction Long None := 0
HelpRequest := 1
ServiceRequest := 2
MaintenanceRequest := 3
SecurityAlert := 4
Log := 5
None := 0 Action performed when
parameter exceeds
treshold condition
ParameterXXAdvice
WhenReturnToNormalRange
Long None := 0
HelpRequest := 1
ServiceRequest := 2
MaintenanceRequest := 3
SecurityAlert := 4
Log := 5
None := 0 Action performed when
parameter returns to
normal range
Command01 – Command10
CommandXXName Text Max length = 50 Empty Name of command,
which can be remotely
performed from CSM
CommandXXDescription Text Max length = 50 Empty Description of
command
Notes
▪ Only named Parameters can be monitored by CSM
▪ Only named Commands can be remotely performed by CSM. See chapter Programming, how to perform
this commands.